Select bit assignment and set the rightmost number to 1. Note: To make sure that gradation reproducibility is guaranteed, perform Initialize + Image Stabilization, Gradation Adjustment and input the previous Dmax density adjustment value (if known) in Service Mode.Į. The machine will now detect a new unit has been installed and reset the life counter. Close the front door and power cycle the machine. Touch key number 3 to change it from a highlighted state to a non-highlighted state.

bizhub c452 error code t81

Open the front door, enter the Service Mode, select then. This mode is used for troubleshooting purposes only and temporarily disables the detection of new drums or developing units. The New Release Disable mode has been activated. it is known to cause weird issues with iu's.ġ. Code: C0204 Description: Tray 2 feeder up/down abnormality The tray 2 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started. i would check resistance on all of your grounds.Īlso you may check to see if new release disable mode has been accidentally activated. you need to check the pin outs and see where the grounding is occurring in the harness.

bizhub c452 error code t81

Sounds like you are having a wiring issue more than a software issue.